Skip to content

m/z recalibration

An instrument drifts. When a spectrum is identified, its matched fragments are the only peaks whose true m/z is known, so they are what the drift can be measured against. recalibrate fits that measurement and applies it to every peak in the spectrum, matched or not.

This is a per-spectrum correction from one PSM's matches. It is not a run-wide or retention-time-dependent calibration model, and it does not touch the precursor.

One call

import numpy as np
import peptacular as pt
from spxtacular import Spectrum, match_fragments, recalibrate

# A spectrum of the b and y ions of PEPTIDESK, 4 ppm high across the whole range.
fragments = pt.fragment("PEPTIDESK", ion_types=("b", "y"), charges=(1,))
true_mz = np.array(sorted(f.mz for f in fragments))
spectrum = Spectrum(mz=true_mz * (1 + 4.0e-6), intensity=np.full(len(true_mz), 1000.0))

matches = match_fragments(spectrum, fragments, tolerance=0.02)
fixed = recalibrate(spectrum, matches)

print(round(fixed.calibration.offset_ppm, 3))      # 4.0
print(np.allclose(fixed.mz, true_mz, rtol=1e-9))   # True

A new spectrum comes back, as with every other transform; pass inplace=True to correct the one you have. intensity, charge, im and iso_score are carried over unchanged and share no array with the input.

What is fitted, and what it is fitted on

Each MatchedFragment already carries the signed error of its peak against the theoretical m/z, in ppm. Those errors are fitted against observed m/z:

model Fitted Correction applied
"offset" (default) one number, ppm = a mz / (1 + a * 1e-6)
"linear" ppm = a + b * mz the same, with a + b * mz in place of a

estimator chooses how. "median" takes the median signed error, which a minority of mis-assigned matches cannot move; "least_squares" takes the mean. The default is the median for a measured reason — on the real PSM behind the package's own figure (mzspec:PXD000561:Adult_Frontalcortex_bRP_Elite_85_f09:scan:17555, VLHPLEGAVVIIFK, 22 matched b/y ions from 147 to 1242 m/z) the median signed error is +0.790 ppm and the mean is +0.908, a 0.12 ppm difference created by a single +5.46 ppm outlier out of 22. The median offset takes the mean absolute error from 1.19 ppm to 0.84 ppm and leaves matched_fraction unchanged.

The linear model is opt-in, because the slope spends a degree of freedom that one outlier can pull: on the same PSM it tightens the residual spread from 1.40 to 1.29 ppm while leaving a larger mean absolute error. It is for an instrument whose error genuinely fans out with m/z, which is the shape mass_error_plot is there to show you. It is fitted by least squares, so it requires estimator="least_squares" rather than silently changing the estimator you asked for.

One pass only. There is no refit-and-rematch loop, which is where a recalibration starts agreeing with its own errors.

When it refuses

recalibrate raises SpxtacularError rather than returning a spectrum it cannot stand behind. Never a silent no-op, and never a half-fit:

  1. Fewer than min_matches matched fragments (8). With fewer points the answer is whichever ions happened to match.
  2. A matched m/z span below min_mz_span (200 Da), for model="linear" only. A slope fitted over a narrow span is extrapolation across the rest of the spectrum.
  3. A correction above max_abs_ppm (50) anywhere in the spectrum's m/z range. That is a wrong peptide or the wrong tolerance unit, not a calibration drift.
  4. Fewer than min_matches distinct peaks: two fragments matching one peak are one observation, not two.
  5. A decharged spectrum. A neutral mass is not an m/z, so recalibrate before decharge(), not after.
  6. A non-finite fitted coefficient.
import numpy as np
import peptacular as pt
from spxtacular import Spectrum, match_fragments, recalibrate
from spxtacular.errors import SpxtacularError

fragments = pt.fragment("PEPTIDESK", ion_types=("b", "y"), charges=(1,))
true_mz = np.array(sorted(f.mz for f in fragments))
spectrum = Spectrum(mz=true_mz * (1 + 4.0e-6), intensity=np.full(len(true_mz), 1000.0))
matches = match_fragments(spectrum, fragments, tolerance=0.02)

try:
    recalibrate(spectrum, matches[:4])
except SpxtacularError as error:
    print(error)  # names min_matches and what it got

Each message names the quantity and the threshold, so a caller can decide whether to lower the bar deliberately or leave the spectrum alone.

What it records

The returned spectrum carries a CalibrationProvenance on calibration, beside the deconvolution record:

import numpy as np
import peptacular as pt
from spxtacular import Spectrum, match_fragments, recalibrate

fragments = pt.fragment("PEPTIDESK", ion_types=("b", "y"), charges=(1,))
true_mz = np.array(sorted(f.mz for f in fragments))
spectrum = Spectrum(mz=true_mz * (1 + 4.0e-6), intensity=np.full(len(true_mz), 1000.0))
matches = match_fragments(spectrum, fragments, tolerance=0.02)

record = recalibrate(spectrum, matches).calibration
print(record.model, record.estimator)                      # offset median
print(record.n_matches, record.n_unique_peaks)             # 18 18
print(round(record.residual_ppm_sd, 6))                    # 0.0
print(round(record.correction_ppm(1000.0), 3))             # 4.0

residual_ppm_sd and residual_ppm_mad are the spread the correction left behind, which is how a caller sees a fit that explained nothing: a median offset that leaves a 20 ppm residual spread has found a wrong peptide, not a drift.

The record survives to_dict(), to_json(), save() and load(), and is part of the packaged JSON Schema (spectrum schema version 3; versions 1 and 2 predate it and read back with no calibration). Peak-list writers drop it, as they drop the other provenance.

Recalibrating twice keeps both corrections:

import numpy as np
import peptacular as pt
from spxtacular import Spectrum, match_fragments, recalibrate

fragments = pt.fragment("PEPTIDESK", ion_types=("b", "y"), charges=(1,))
true_mz = np.array(sorted(f.mz for f in fragments))
spectrum = Spectrum(mz=true_mz * (1 + 4.0e-6), intensity=np.full(len(true_mz), 1000.0))
matches = match_fragments(spectrum, fragments, tolerance=0.02)

once = recalibrate(spectrum, matches)
again = recalibrate(once, match_fragments(once, fragments, tolerance=0.02))

print(round(again.calibration.previous.offset_ppm, 3))  # 4.0
print(round(again.calibration.offset_ppm, 6))           # 0.0, nothing left to correct

Where it fits in a pipeline

Match, recalibrate, then re-match or re-score on the corrected axis:

import numpy as np
import peptacular as pt
from spxtacular import Spectrum, match_fragments, recalibrate, score

fragments = pt.fragment("PEPTIDESK", ion_types=("b", "y"), charges=(1,))
true_mz = np.array(sorted(f.mz for f in fragments))
spectrum = Spectrum(mz=true_mz * (1 + 4.0e-6), intensity=np.full(len(true_mz), 1000.0))

matches = match_fragments(spectrum, fragments, tolerance=0.02)
fixed = recalibrate(spectrum, matches)

before = score(spectrum, fragments, tolerance=0.02)
after = score(fixed, fragments, tolerance=0.02)
print(round(before["mean_ppm_error"], 3), "->", round(after["mean_ppm_error"], 3))

A tighter mean error on the same matches is the point; a matched_fraction that falls after recalibration means the fit moved the axis the wrong way, and is worth looking at rather than ignoring.