Fragment matching, scoring and reporter ions

spxtacular provides two functions for peptide-spectrum match (PSM) scoring: match_fragments() for matching and score() for computing all metrics at once.


match_fragments()

from spxtacular import match_fragments
import peptacular as pt

fragments = pt.fragment("PEPTIDE", ion_types=("b", "y"), charges=(1, 2))
matches = match_fragments(
    spectrum,
    fragments,
    tolerance=0.02,
    tolerance_unit="da",         # "da" or "ppm"
    peak_selection="closest",    # "closest", "largest", or "all"
)
# matches: list[MatchedFragment], sorted by peak index

Parameters:

Parameter Default Description
spectrum Spectrum to search
fragments Iterable of fragment objects from peptacular
tolerance 0.02 Matching tolerance
tolerance_unit "da" "da" or "ppm"
peak_selection "closest" How to resolve multiple peaks within tolerance (see below)
is_monoisotopic True Forwarded to the constructed Fragment objects when fragments is a dict[(IonType, charge_state), list[float]] (peptacular's fast_fragment output); otherwise has no effect

peak_selection modes:

Mode Behaviour
"closest" Keep the single peak with smallest m/z error (default)
"largest" Keep the single peak with highest intensity
"all" Keep every peak within tolerance

Return value:

match_fragments() returns a list[MatchedFragment], sorted by ascending peak_index. Each MatchedFragment carries both the fragment and the matched peak's metadata:

Field Description
fragment The matched Fragment object
peak_index Index of the matched peak in spectrum.mz/spectrum.intensity
peak_mz m/z of the matched peak
peak_intensity Intensity of the matched peak
intensity_pct peak_intensity / total_spectrum_intensity * 100
ppm_error Signed error: (peak_mz - theoretical_mz) / theoretical_mz * 1e6
da_error Signed error: peak_mz - theoretical_mz

Example:

matches = match_fragments(spec, fragments, tolerance=10, tolerance_unit="ppm")
for m in matches:
    print(f"  Peak {m.peak_index} ({m.peak_mz:.4f} m/z) matched {m.fragment} (Δ={m.ppm_error:+.1f} ppm)")

score()

Runs match_fragments() internally and returns all scoring metrics as a dict.

from spxtacular import score

result = score(spectrum, fragments, tolerance=10, tolerance_unit="ppm")

Parameters:

Parameter Default Description
spectrum Spectrum to score against
fragments Iterable of fragment objects from peptacular
tolerance 0.02 Matching tolerance
tolerance_unit "da" "da" or "ppm"
peak_selection "closest" How to resolve multiple peaks within tolerance — "closest", "largest", or "all"
predicted_intensities None Optional predicted intensity for every fragment, in the same order. Enables the literature spectral-angle metric

Returned metrics:

Key Description
hyperscore Base-10 matched-intensity dot product plus log-factorial terms per ion series
probability_score -log10 P(>= k matches by chance)
total_matched_intensity Sum of matched peak intensities
matched_fraction Fraction of theoretical ions matched
intensity_fraction Fraction of total spectrum intensity explained by matches
mean_ppm_error Mean absolute ppm error of matches
spectral_angle Spectral angle vs predicted_intensities (0–1). Without a prediction, a coverage/evenness fallback — see below
longest_run Longest consecutive ion sequence matched

Neutral-loss and isotope variants of the same fragment share (ion_type, position) and are collapsed to avoid inflating factorial terms in the hyperscore.

Hyperscore

The score uses log10(sum(I_matched)) + sum_s(log10(n_s!)), with unit theoretical intensities. Each observed peak contributes once to the intensity sum. Each distinct (ion_type, position) contributes once to its series count, so charge, neutral-loss, and isotope variants do not inflate the factorial terms. Missing series contribute 0! = 1, and one-sided evidence can have a positive score. No matches or a nonpositive matched-intensity sum returns zero.

This follows the dot-product/factorial structure described in OpenMS's HyperScore documentation. The base-10 logarithm, unit theoretical intensities, preprocessing, and duplicate handling are explicit spxtacular conventions. Scores are not guaranteed numerically interchangeable with X!Tandem, OpenMS, Comet, or MSFragger outputs.

Warning

Versions through 0.6.0 multiplied the intensity sums of different ion series. That was a different heuristic, incorrectly described as identical to X!Tandem. Recompute stored scores and retune thresholds when upgrading. Scaling all intensities by s now shifts a positive-signal score by log10(s), once rather than once per ion series. Normalized inputs can produce negative scores.

Spectral angle

Supply predicted_intensities — one value per fragment, in the same order — and you get the spectral angle of the literature (Toprak et al.; the metric Prosit and Spectronaut report):

result = spx.score(
    spec, fragments,
    tolerance=10, tolerance_unit="ppm",
    predicted_intensities=predicted,   # aligned with `fragments`
)

It is a cosine, so it is scale-invariant: 1.0 means the observed pattern matches the prediction.

Warning

Without predicted_intensities there is nothing to compare against, and the value falls back to a cosine against a flat reference — which measures intensity evenness × coverage, not similarity to a predicted spectrum. A perfect match with realistic intensities [100, 50, 10, 1] scores 0.509 that way. Do not compare the fallback to published spectral angles.

Example:

import peptacular as pt
from spxtacular import MzmlReader, score

with MzmlReader("run.mzML") as reader:
    # reader.ms2 is an iterable lookup object, not an iterator — wrap it in iter()
    spec = next(iter(reader.ms2))

fragments = pt.fragment("ACDEFGHIK", ion_types=("b", "y"), charges=(1, 2))
result = score(spec, fragments, tolerance=10, tolerance_unit="ppm")

print(f"Hyperscore:      {result['hyperscore']:.3f}")
print(f"Spectral angle:  {result['spectral_angle']:.3f}")
print(f"Matched ions:    {result['matched_fraction']:.1%}")

Spectrum-to-spectrum similarity

score() answers how well does this peptide explain this spectrum. These answer how alike are these two spectra, which is what spectral library search, replicate comparison and clustering are built on.

from spxtacular import cosine, modified_cosine, entropy_similarity

cosine(query, reference, tolerance=20, tolerance_unit="ppm")   # 0-1
entropy_similarity(query, reference, tolerance=0.02)           # 0-1
Function What it is
cosine The standard spectral dot product: sqrt-transformed intensities, unit-normalised, peaks matched one-to-one
modified_cosine Cosine that also matches peaks displaced by the precursor mass difference — the GNPS molecular-networking metric
entropy_similarity Unweighted entropy similarity with one-to-one greedy peak alignment

All three are symmetric, scale-invariant, and bounded in [0, 1]: identical spectra score 1, spectra with no shared peaks score 0.

Matching is one-to-one — a peak may back at most one match, resolved greedily by descending contribution. Allowing every pair within tolerance instead would let one intense peak match several neighbours and push the score past 1.

Modified cosine

Two spectra of the same molecule differing by one modification share many fragments, but every fragment containing the modified site is shifted by the modification's mass. A plain cosine reads those as mismatches:

# same peptide, one +79.966 phospho on the C-terminal half
cosine(a, b, tolerance=0.02)                              # 0.53 - looks unrelated
modified_cosine(a, b, 500.0, 579.966, tolerance=0.02)     # 1.00 - recovered

It reduces exactly to cosine when the two precursors are equal.

entropy_similarity uses the unweighted entropy expression. It does not apply entropy-dependent intensity weights or automatically remove precursor and noise peaks. Negative intensities are clipped to zero and each spectrum is normalized to a probability distribution. Preprocess both inputs consistently. The MS Entropy reference distinguishes weighted and unweighted variants and documents its own cleaning defaults. The tests include independent values for unambiguous peak alignments. They do not establish that one metric outperforms another for compound identification.

Isobaric reporter ions (TMT, TMTpro, iTRAQ)

spxtacular reads the reporter-ion intensities of isobaric-labelled spectra: TMT 0/2/6/10/11, TMTpro 0/16/18 and iTRAQ 4/8. Channel names and reporter m/z come from tacular's ISOBARIC_TAG_LOOKUP, which computes each reporter m/z from its isotopic composition, so no reporter mass is typed into spxtacular.

import spxtacular as spx

spec = next(iter(spx.Reader("run.mzML").ms2))
ions = spec.reporter_ions("TMT10")          # or spx.extract_reporter_ions(spec, "TMT10")
ions.channels        # ('126', '127N', '127C', ..., '131N')
ions.intensity       # one value per channel, 0.0 where no peak was found
ions.ppm_error       # observed - theoretical m/z in ppm, NaN where no peak was found
ions["127N"]         # one channel's intensity

table = spx.reporter_ion_table(spx.Reader("run.mzML"), "TMTpro18", include_errors=True)
# spectrum_index  scan_number  native_id  ms_level  rt  126  127N  ...  135N  126_ppm_error ...

Plex names

Pass a name or alias from tacular, case-insensitive: TMT0, TMT2, TMT6, TMT10 (TMT10plex), TMT11, TMTpro0, TMT16 (TMTpro16), TMT18 (TMTpro18), iTRAQ4, iTRAQ8, or a tacular.IsobaricTagInfo. ReporterIons.plex is tacular's name for it ("TMT18" for "TMTpro18"). An unknown name raises SpxtacularError listing the valid ones.

How peaks are picked

Choice Behaviour
Tolerance tolerance=20.0, tolerance_unit="ppm" by default ("da" also accepted). The closest channels, the TMT/TMTpro N/C pairs, are 6.32 mDa (about 47-50 ppm) apart, so +/-20 ppm windows never overlap. A tolerance that makes two windows overlap raises SpxtacularError.
Several peaks in a window The most intense peak is used (ties: lowest m/z).
No peak in a window Intensity 0.0; observed_mz and the error are NaN; found is False. Zero keeps sums, ratios and the impurity correction well defined, and NaN in the error columns keeps "not found" visible.
Tolerance limit The overlap error names the largest tolerance that fits, e.g. "Use a tolerance below 24.28 ppm" for TMT10.
Input Centroided spectra in m/z; the m/z array need not be sorted. A decharged spectrum (neutral masses) or NaN/inf intensities raise SpxtacularError.

Many spectra

reporter_ion_table(spectra, plex, ...) takes any iterable of spectra (a list, a generator, reader.ms2). Any object with an ms2 attribute (every spxtacular reader) is read through .ms2, even if it is iterable itself, so a reader gives its MS2 spectra. It returns one row per spectrum: spectrum_index (position in the input), scan_number, native_id, ms_level, rt (None for a plain Spectrum), one float column per channel, and with include_errors=True a <channel>_ppm_error column per channel. ms_level= keeps only spectra of that level; for SPS-MS3 data pass an iterable of the MS3 spectra (e.g. iter(reader)) with ms_level=3.

Isotope impurity correction

Each TMT/iTRAQ reagent lot ships with a sheet of isotope impurities: for every channel, the percentage of its reporter signal that appears 2 or 1 Da below and 1 or 2 Da above. Pass the sheet as impurities= and the intensities are corrected:

lot = {
    "126":  {"-2": 0.0, "-1": 0.0, "+1": 7.0, "+2": 0.2},
    "127N": {"-2": 0.0, "-1": 0.4, "+1": 6.5, "+2": 0.0},
    # ... one row per channel; channels left out are taken as pure
}
ions = spec.reporter_ions("TMT10", impurities=lot)
ions.raw_intensity   # what was measured
ions.intensity       # corrected

table = spx.reporter_ion_table(reader, "TMT10", impurities=lot, normalize="sum")

A pandas.DataFrame with channels as the index and shifts as columns works as well. Empty cells (None, NaN) are 0. Column labels are:

  • Numbers (-2, -1, +1, +2): always that many 13C, never 15N.
  • Explicit substitutions: "-13C", "+2x13C", "-15N", "+13C+15N", "-18O".
  • A main-peak column (0, "0", "main", "reporter", "monoisotopic", any case): ignored, because the main peak is always 100 - sum(impurities).

TMT10/11 and TMTpro N channels carry a 15N, and a reagent missing it loses 0.997 Da, not the 1.003 Da of a 13C. The two land 6.3 mDa apart, on different channels. If your sheet lists 15N and 13C impurities of N channels separately (newer Thermo TMTpro sheets do), label the 15N columns "-15N"/"+15N"; a numeric -1 there is read as 13C and placed on the wrong m/z.

isotope_correction_matrix(plex, lot) returns the matrix M that is solved, observed = M @ true. M[i, j] is the fraction of reagent j's signal seen in channel i:

  • A reagent keeps 100 - sum(its impurities) percent in its own channel.
  • Each impurity goes to the channel nearest the shifted reporter m/z, if it is within min(0.02 Da, half the plex's smallest channel spacing), as in OpenMS. That is 0.02 Da for TMT6 and iTRAQ, whose channels are about 1 Da apart, and about 3.2 mDa for TMT10/11 and TMTpro, whose N/C pairs are 6.32 mDa apart. So the -1 of TMT 128C goes to 127C and of 128N to 127N, since they differ by one 13C.
  • An impurity that lands on no channel of the plex is lost signal and only lowers the diagonal. In TMT10 the -1 (13C) of 127N lands 6.3 mDa below 126 and the +1 of 130C lands on the 131C position, 6.3 mDa above 131N: neither is inside a picking window, so neither is counted. In TMT11 the +1 of 130C goes to 131C.

You can also pass a precomputed square matrix as impurities=, or call correct_isotope_impurities(intensities, matrix_or_lot, plex=...) (plex is keyword-only) on your own arrays (one spectrum or a 2-D array of many).

Non-negativity. Each spectrum is first solved exactly. With noise, the exact solution can go slightly negative in a weak channel next to a strong one. Those spectra are re-solved by non-negative least squares (a small Lawson-Hanson NNLS in numpy, since scipy is not a dependency). That gives the exact answer whenever it is already non-negative. Otherwise it gives the closest non-negative fit, which, unlike clipping negatives to zero, passes the remainder on to the neighbouring channels.

Normalization

normalize="sum" divides each spectrum's channels by their sum and normalize="max" by the largest channel, after correction. A spectrum with no reporter signal stays all zero.